moving jaw plate


(2) If the shaft is different from the stuffing box axis, it is mainly due to processing errors and incorrect installation. Then pay attention to check whether the installation is correct after installation. If the sealing water ring is badly worn, a new water ring needs to be replaced. If the sealing water pipe is blocked, the sealing water cannot enter the middle of the packing, resulting in rapid wear of the packing, resulting in material leakage, you should dredge the blocked water pipe and keep the sealing water clean.

...

  • 1.The selection of the pump is too large, and the flow and head are larger than the actual condition due to improper selection of the coefficient. This situation makes the pump in the operation process, cavitation phenomenon, resulting in premature damage of the pump flow parts under the combined action of cavitation and abrasion, in the case of serious cavitation, the pump will produce vibration and noise, and even lead to a sharp decline in the flow, head and efficiency of the pump can not run; In addition, the pump in the operation of large flow, will also cause motor overload, heat, serious will burn the motor.
  • ...