wholesale horizontal slurry pump
Content introduction
Problem: pump does not water, pressure gauge and true empty meter pointer beat violently.
Problem: pump does not water, pressure gauge and true empty meter pointer beat violently.
- Drill Rods These are the connecting links between the surface rig and the drill bit, allowing for the transmission of energy and air.
Before use, check the mechanical structure and the hydraulic system, as well as the water level in the diesel engine's water tank and the motor oil level. If everything is normal, you can start the diesel engine. After running at a low speed without load for 3-5 minutes, you can begin work.
After 100 hours of operation, replace the engine oil, gear oil, motor oil, and brake fluid.
The reason:
The suction pipe is not filled with water
Blocked suction line or inadequate valve opening
The inlet pipe of the pump, the meter or the stuffing box are serious
The suction pipe is not filled with water
Blocked suction line or inadequate valve opening