Wire mesh welding after galvanized is through the end of the welding and then the cold company to make wire mesh wire mesh steel mesh construction mesh floor heating mesh galvanized or hot galvanized. After the first galvanized welding is to change the wire mesh, after the end of welding can see the welding spot; The two processes are different prices are also very different, the cost of the first plating after welding is low, the appearance is smooth, and the cost of the first welding after plating is higher, not easy to rust.
Electric galvanized wire direct selling is in the plating tank through the current one-way to gradually zinc plating on the metal appearance, the production speed is slow, uniform coating, thin thickness, usually only 3-15 microns, bright appearance, poor corrosion resistance, generally a few months will rust. Compared with hot dip galvanizing, the production cost of electric galvanizing is lower. The difference between cold galvanizing and hot galvanizing: the difference between cold galvanizing and hot galvanizing is that the amount of zinc is different. They can be identified from the color. The color of cold galvanizing is shiny silver white with yellow. Hot dip galvanizing shiny white.
- 2. Zinc layer uniformity: zinc layer uniformity also has an important impact on corrosion resistance. If the zinc layer is not uniform, there are local defects or insufficient thickness areas, it is easy to form corrosion points, resulting in the destruction of the entire zinc layer.
- 2. Take out the items in the cage. First, rinse most of the dirt off the cage with water, and then wipe the dirt around it with a wet towel; And then clean the cage.
1, galvanized silk mesh molding sheet must be packed with flat hard materials, to avoid improper packaging and eternal deformation. It is important that each package and roll of raw material be marked with product name, standard, quantity, trademark, lot number, manufacturer, date of production, packing symbol, inspector code and inspection certificate.
Cattle net in the outdoor use of a long time will inevitably show rust corrosion, this time the use of cattle net life depends on the maintenance of the product is not in place, we all know that cattle net if long exposure to harsh environment, the service life will be greatly reduced. How long does a normal cattle net last?
Post time: 06-05-22- Mainly suitable for flat welding.
Post time: 22-07-22Plastic spraying is also we often talk about electrostatic powder spraying, it is the use of electrostatic generator to make plastic powder charged, adsorption on the surface of the iron plate, and then through 180~220 DEG C baking, so that the powder melting adhesion on the metal surface, plastic spraying products are used for indoor use of the box, paint film flat or matte effect. Spray powder mainly acrylic powder, polyester powder, etc.
- 2, the cage must be strong
Fence use: generally used as a fence is a plastic-impregnated welded wire mesh with a height of 1.2 meters to 2 meters. Most of the mesh holes are 6cm, and the wire diameter varies from 2mm to 3mm.
- With a large pickpocket for the steel wire, into the zinc liquid before the surface of the zinc ash stirring; Use a small outlet for steel wire galvanized; Zinc pot steel wire outlet in 30 minutes, with the pickpocket back and forth, until the large, floating zinc residue into brown yellow, real zinc ash, zinc ash surface. The zinc ash taken out should be brown yellow real zinc ash, zinc surface, effectively reduce the zinc consumption. This is one of the biggest measures to reduce zinc consumption, and it is a real problem, which has not been solved for many years.
- Galvanized iron wire is divided into hot galvanized wire and cold galvanized wire (electric galvanized wire) is made of low carbon steel, after drawing molding, pickling rust removal, high temperature annealing, hot galvanized, cooling and other processes. Galvanized iron wire has good toughness and elasticity, zinc content can reach 300 grams/square meter. It has the characteristics of thick galvanized layer and strong corrosion resistance. The products are widely used in construction, handicrafts, wire mesh, galvanized hook mesh, spackle mesh, highway fence, product packaging and daily civilian and other fields.
Post time: 28-04-23
Post time: 11-04-23
Post time: 13-06-24- Post-plating (passivation, hot melting, sealing and dehydrogenation, etc.) for the purpose of enhancing protective properties, decoration and other special purposes. After galvanized, chromate passivation or other conversion treatment is generally required to form the corresponding type of conversion film, which is one of the key processes to ensure the quality of post-plating.
- The service condition and service life of galvanized iron wire or components are closely related to the thickness of the coating. The more strict the use conditions and the longer the service life, the thicker the required layer of galvanized iron wire should be. Different products, according to the specific environment (temperature, humidity, rainfall, atmospheric composition, etc.) to determine the expected service life of the coating thickness, blind thickening will cause all kinds of waste. But if the thickness is insufficient, it will not reach the expected service life requirements. Different manufacturers, according to their own equipment conditions, in the case of determining the plating, the first preparation of a more complete and reasonable process flow, clear plating parameters, control plating solution concentration, standard operation.
- 3. The surface adhesion of stainless steel pet cage contains acid, alkali and salt substances (such as alkali and lime water splashing on the decoration wall), which causes local corrosion.
- Two, the influence of steel wire surface roughness
In order to pack and bundle galvanized wire on the surface of the deposit layer to remove the surface film, surface inclusion and other defects can be found and treated by conventional technology; Excess foam is caused by soaps and saponable fatty surfactants being brought into the tank. Moderate foam formation rates may be harmless. Small homogeneous particles of large denier present in the tank can stabilize the foam layer. To remove surface active substances by matting with activated carbon. Or filtration to make the foam less stable, which are effective measures; Other measures should also be taken to reduce the intake of surfactant. The electroplating speed can be significantly reduced by the introduction of organic matter. Although the chemical formula is conducive to a high deposition rate, the coating thickness cannot meet the requirements after the organic matter is loaded, so activated carbon can be used to treat the tank.
- (4) Stop the use of more than two strands of galvanized iron wire around the operation method.